Description

Steps that led to the error

  1. Start Circle
  2. Perform a vote
  3. Put the computer to sleep mode
  4. Wake the computer
  5. Perform "Abstimmungen"-"Aktualisieren"

Observation

  • The error message shown below was displayed.
  • When the error message is dismissed, the UI is ready for input again. Another click on "Aktualisieren" results in the same error message (endless).
  • The user has no other chance than to close the program and restart it.

Expectation

  • The software catches the error gracefully and either tries to reconnect, restart the application or asks the user to restart it herself.

Trace

Operating system:    Microsoft Windows NT 6.1.7601 Service Pack 1
Program version:     1.1.4.0
Library version:     1.1.4.0
Message:             Unable to write data to the transport connection: An established connection was aborted by the software in your host machine.

System.IO.IOException: Unable to write data to the transport connection: An established connection was aborted by the software in your host machine. ---> System.Net.Sockets.SocketException: An established connection was aborted by the software in your host machine
   at System.Net.Sockets.Socket.Send(Byte[] buffer, Int32 offset, Int32 size, SocketFlags socketFlags)
   at System.Net.Sockets.NetworkStream.Write(Byte[] buffer, Int32 offset, Int32 size)
   --- End of inner exception stack trace ---
   at Pirate.PiVote.Circle.CircleController.GetVotingList()
   at Pirate.PiVote.Circle.Master.RefreshInternal()
   at Pirate.PiVote.Circle.Master.RefreshVotings()